current location:Home»News & Events»FAQ-How far can thermal imaging be measured?FAQ

How far can thermal imaging be measured?

source:  release time:2018-01-08   Click volume:175

The detection distance of the thermal imaging = measured target size ÷ IFOV, so the smaller the spatial resolution (IFOV), the farther it can be measured. For example: the transmission line clip size is generally 50mm, if using the Fluke Ti25 thermal imaging, the IFOV is 2.5mRad, the farthest detection distance of 50 ÷ 2.5 = 20m